How the Military Disposes of Lithium Batteries: TB-43-0134 Explained

A lithium-ion battery may be small enough to carry in one hand, but its disposal can create a significant compliance, safety, and procurement responsibility for a military installation.
When batteries reach the end of their useful life, the installation must determine what the battery is, how it should be classified, where it can be stored, how it can be transported, and which facility is authorized to recycle or dispose of it. That process becomes more complicated when batteries are swollen, punctured, recalled, or missing their original documentation.
For Army installations, TB-43-0134, Battery Disposition and Disposal, provides an important starting point. The manual does not replace installation environmental procedures, state requirements, Department of Transportation rules, or current DLA Disposition Services instructions. Instead, it helps establish the framework for safe battery disposition and disposal.
The central lesson is straightforward: lithium-ion battery recycling is not simply a waste pickup. It is a controlled chain of custody.
TB-43-0134 requires coordination, not improvisation
Army installations generally coordinate battery disposition through the Installation Environmental Office and the Defense Reutilization and Marketing Office, now operating within the DLA Disposition Services structure.
That coordination matters because the same battery may be treated differently depending on its chemistry, condition, state regulations, and intended destination. The Army Battery program identifies lithium-ion batteries in the BB-2XXX series as nonhazardous solid waste under the federal table in some circumstances. However, state requirements may be more stringent, and damaged or mishandled batteries can present additional hazards.
The Army’s battery disposal guidance directs installations to contact the local Installation Environmental Office and DLA Disposition before turn-in. It also cautions that waste batteries should not be accumulated for more than 90 days, or more than one year when managed under the federal Universal Waste Rule.
That distinction is important during an inspection. A storage area that appears orderly may still create a compliance concern if the installation cannot show:
- When the batteries became waste
- How the batteries were classified
- Which office approved the disposition pathway
- Where the batteries were sent
- Whether the receiving facility was authorized
- How damaged or recalled batteries were segregated
- Whether transport and recycling records were retained
The paper trail is not administrative decoration. It is evidence that the installation maintained control of the waste stream.
Lithium-ion batteries are regulated even when they look harmless
Under the federal Resource Conservation and Recovery Act, most discarded lithium-ion batteries are likely to be hazardous waste because they may exhibit ignitability or reactivity, commonly associated with waste codes D001 and D003.
The Environmental Protection Agency recommends that businesses consider managing used lithium batteries under the federal Universal Waste regulations in 40 CFR Part 273. Both rechargeable lithium-ion batteries and single-use lithium batteries can fall within the universal waste battery framework.
Universal waste requirements include controls for:
- Container condition and compatibility
- Battery and container labeling
- Accumulation time
- Employee training
- Release response
- Final destination
- Recordkeeping
A universal waste shipment does not automatically require a hazardous waste manifest under federal rules. That does not mean the shipment is unregulated. Department of Transportation requirements still apply to lithium batteries moving in commerce, including packaging, marking, labeling, shipping papers, emergency information, and hazmat employee training under 49 CFR Parts 171 through 180.
State regulations may also impose requirements beyond the federal baseline. This is one reason an installation should avoid treating lithium-ion batteries as ordinary scrap.
Storage is where many installations experience the greatest risk
Batteries often accumulate because each individual turn-in appears too small to justify a separate project. Over time, those small quantities become a larger inventory with a larger fire load and a less reliable record.

For batteries awaiting recycling or disposal, the storage area should be organized around isolation, inspection, and traceability. Practical controls include:
- Store batteries in a cool, dry, well-ventilated area
- Protect batteries from impact, crushing, puncture, and short circuits
- Cover exposed terminals with nonconductive tape or use appropriate individual packaging
- Keep containers closed, stable, and compatible with the battery contents
- Separate damaged, defective, and recalled batteries from intact batteries
- Mark containers with an appropriate universal waste battery label
- Record the date batteries entered the accumulation area
- Maintain an inventory by battery type, NSN, condition, quantity, and status
- Coordinate fire detection and suppression requirements with the installation fire department
- Perform regular visual inspections and document findings
EPA also recommends climate-controlled storage where possible, separate storage away from occupied spaces and flammable materials, thermal inspections, and an emergency evacuation plan.
TB-43-0134 includes fire control and suppression guidance for military battery operations. Installation personnel should not create a one-size-fits-all response plan for lithium-ion battery events. The appropriate response depends on the battery, voltage, surrounding equipment, fire conditions, and electrical hazards. The installation fire department and environmental office should be involved before an emergency occurs.
Damaged batteries require a different pathway
A swollen, leaking, punctured, overheated, or recalled battery should not be placed in the same container as ordinary spent batteries.
Damaged batteries may be more likely to experience thermal runaway during storage, handling, or transportation. They should be removed from service, isolated from flammable materials, and managed according to installation procedures and qualified technical direction. Personnel should not continue charging or using a visibly damaged battery.
Under EPA guidance, a damaged battery may be managed as universal waste only when the damage does not breach an individual cell casing. A battery with a breached casing, leakage, or a condition that creates an immediate hazard may require a more controlled hazardous waste pathway.
Damaged, defective, or recalled lithium batteries also have special transportation requirements. They cannot be transported by air and must meet the packaging requirements in 49 CFR 173.185(f).

This is where installations often face a practical gap. The environmental office may know that a swollen pack is unsafe, while the storage team may not know where to place it. A carrier may be qualified for ordinary lithium-ion batteries but not damaged or recalled batteries. A recycler may accept intact packs but lack the equipment or authorization to process high-risk material.
A compliant battery disposal plan must address those exceptions before they appear at the loading dock.
DLA Disposition Services and the procurement question
DLA Disposition Services treats lithium-ion batteries as controlled disposition items rather than ordinary scrap. The expected pathway is recycling or authorized hazardous waste management through the applicable disposal and recycling contract structure.
For acquisition teams, the relevant industry classifications commonly include:
- NAICS 562920, Materials Recovery Facilities
- NAICS 562211, Hazardous Waste Treatment and Disposal
The correct code depends on the work described in the solicitation and the condition of the material. Intact batteries routed for materials recovery may fit a recycling-focused requirement. Damaged, leaking, reactive, or otherwise regulated batteries may require hazardous waste treatment and disposal capabilities.
Installations reviewing a Disposal and Recycling Master CLIN should examine the performance work statement for requirements related to:
- Battery profiling and classification
- Packaging and labeling
- DOT compliance
- Approved transport providers
- DLA Qualified Facilities List requirements
- Recycling percentages or recycling priority
- Certificates of recycling or destruction
- Weight tickets and receiving records
- Final destination reporting
- Handling of damaged, defective, or recalled batteries
DLA maintains information about hazardous waste disposal and its Qualified Facilities List. Because solicitations and contract requirements change, procurement personnel should confirm current language through DLA and SAM.gov.
The paper trail is the deliverable
The most effective battery disposal programs do more than remove containers from a storage area. They produce a defensible record from generation through final recycling or disposal.

An installation should be able to connect the original battery inventory to the final destination through documents such as:
- Inventory and condition reports
- Waste determinations
- Accumulation start dates
- Packaging and inspection records
- Shipping papers
- Bills of lading
- Certificates of recycling
- Certificates of destruction, when applicable
- Weight tickets
- Receiving confirmations
- Photographs of unusual or damaged batteries
- Communications between the environmental office, DLA, contractors, and the receiving facility
When an inspection or audit occurs, the question is rarely only, “Where are the batteries now?” The more important question is, “Can the installation prove what happened to them?”
E.A.L.M., LLC approaches lithium-ion battery recycling and battery storage decommissioning as one connected responsibility. A single accountable partner can help coordinate transport, decommissioning, documentation, and recycling so the installation does not have to manage separate contractors for hazardous materials transportation, electrical work, and final recovery.
Frequently asked questions
Who is responsible for lithium-ion battery disposal?
The installation or generating activity remains responsible for proper classification, storage, coordination, and disposition. The Installation Environmental Office and DLA Disposition Services help establish the approved pathway. A contractor may perform transportation, decommissioning, or recycling services, but contracting the work does not remove the installation’s oversight responsibility.
How long can batteries be stored?
Army guidance cautions against storing waste batteries longer than 90 days, or longer than one year when the batteries are managed under the Universal Waste Rule. The installation should document the applicable pathway, accumulation dates, and any state-specific requirements.
Are damaged, swollen, punctured, or recalled packs handled differently?
Yes. Damaged, defective, and recalled batteries should be isolated from intact batteries and evaluated under specialized handling and transportation requirements. A breached cell casing or active thermal event may require a hazardous waste or emergency response pathway rather than ordinary universal waste handling.
What documentation should an installation keep?
The installation should retain classification records, inventory data, accumulation dates, inspection logs, packaging information, shipping documents, transporter details, receiving confirmations, certificates of recycling or destruction, and communications supporting the final disposition decision.
For teams building or updating a military battery disposal plan now, the first step is not waiting for the storage area to fill. It is identifying the battery inventory, confirming the regulatory pathway, and establishing who will own the chain of custody from storage through certified recycling or disposal.
Suggested headline options
- TB-43-0134 Explained: How Military Installations Dispose of Lithium Batteries
- Lithium-Ion Battery Recycling for Military Installations: A Compliance Guide
- From Storage Room to Recycler: The Military Battery Disposal Process
- Military Lithium Battery Disposal: Storage, DLA Coordination, and Audit Readiness
- Why the Paper Trail Matters in Government Lithium-Ion Battery Recycling
Social promotion captions
LinkedIn caption 1
Lithium-ion battery disposal is not a routine scrap transaction for military installations.
TB-43-0134, RCRA Universal Waste requirements, DOT transportation rules, DLA coordination, and state regulations all affect the final pathway.
The immediate risk is often visible in the storage room. The larger compliance risk is hidden in missing dates, incomplete records, unclear responsibility, and no documented final destination.
E.A.L.M., LLC examines the full chain of custody across battery recycling, storage decommissioning, transportation, and documentation.
Read the full guide: How the Military Disposes of Lithium Batteries: TB-43-0134 Explained
LinkedIn caption 2
A swollen lithium-ion battery should never be treated like an ordinary spent battery.
Military installations need separate procedures for damaged, defective, recalled, leaking, and punctured packs. They also need a documented pathway for storage, transport, recycling, and final disposition.
The question during an audit is not only where the batteries went. It is whether the installation can prove what happened to them.
This new guide explains the practical compliance issues under TB-43-0134 and 40 CFR Part 273.
Short social caption
Military lithium-ion battery recycling requires more than pickup. It requires coordination, safe storage, approved transport, certified recycling, and a complete chain of custody.
Read the guide to TB-43-0134 and the battery disposal process for government installations.